1 |
chuckv |
4 |
module dynamics_utilities |
2 |
|
|
use definitions, ONLY : ndim, DP |
3 |
|
|
use second_deriv, ONLY : alloc_sec_deriv |
4 |
|
|
use parameter, ONLY : DT, file_prefix, write_config_steps,run_time |
5 |
|
|
use xyz_io, ONLY: dump_config |
6 |
|
|
#ifdef MPI |
7 |
|
|
use mpi_module, ONLY : node |
8 |
|
|
#endif |
9 |
|
|
IMPLICIT NONE |
10 |
|
|
PRIVATE |
11 |
|
|
|
12 |
|
|
public :: init_status |
13 |
|
|
public :: init_dynamics_loop |
14 |
|
|
public :: evolve_time |
15 |
|
|
|
16 |
|
|
type, public :: sim_status |
17 |
|
|
real( kind = DP ) :: pot_e |
18 |
|
|
real( kind = DP ) :: kin_e |
19 |
|
|
real( kind = DP ) :: tot_e |
20 |
|
|
real( kind = DP ) :: time |
21 |
|
|
real( kind = DP ) :: temp |
22 |
|
|
end type sim_status |
23 |
|
|
|
24 |
|
|
! . dump status variables |
25 |
|
|
integer :: status_unit = -1 |
26 |
|
|
character(len=80) :: status_file |
27 |
|
|
character(len=*), parameter :: status_fmt ='(4es15.6)' |
28 |
|
|
!. Time constant variables |
29 |
|
|
real( kind = DP), public :: DT2 |
30 |
|
|
real( kind = DP), public :: DTSQRT |
31 |
|
|
real( kind = DP), public :: DTSQ2 |
32 |
|
|
public :: dump_status |
33 |
|
|
|
34 |
|
|
contains |
35 |
|
|
|
36 |
|
|
|
37 |
|
|
subroutine init_status(this_status) |
38 |
|
|
type (sim_status) :: this_status |
39 |
|
|
end subroutine init_status |
40 |
|
|
|
41 |
|
|
|
42 |
|
|
subroutine init_dynamics_loop(this_status) |
43 |
|
|
use force_module, ONLY: calc_forces |
44 |
|
|
use velocity, ONLY: calc_temp |
45 |
|
|
use definitions, ONLY : machdep_lnblnk, machdep_flush |
46 |
|
|
use status, ONLY : info |
47 |
|
|
type (sim_status) :: this_status |
48 |
|
|
logical :: nmflag |
49 |
|
|
logical :: update_nlist |
50 |
|
|
character(len=120) :: msg |
51 |
|
|
|
52 |
|
|
!. define status dump file name |
53 |
|
|
status_file = file_prefix(1:machdep_lnblnk(file_prefix)) // '.status' |
54 |
|
|
write(msg,*) 'Temperatures and energies will be in: ' // trim(status_file) |
55 |
|
|
call info("Init dynamics", msg) |
56 |
|
|
|
57 |
|
|
DT2 = DT/2.0E0_DP |
58 |
|
|
DTSQRT = sqrt(dt2) |
59 |
|
|
DTSQ2 = DT * DT2 |
60 |
|
|
|
61 |
|
|
! . initialize status variables |
62 |
|
|
this_status%pot_e = 0.0E0_DP |
63 |
|
|
this_status%kin_e = 0.0E0_DP |
64 |
|
|
this_status%tot_e = 0.0E0_DP |
65 |
|
|
this_status%time = 0.0E0_DP |
66 |
|
|
this_status%temp = 0.0E0_DP |
67 |
|
|
|
68 |
|
|
|
69 |
|
|
|
70 |
|
|
! allocate second derivative matrix |
71 |
|
|
|
72 |
|
|
call alloc_sec_deriv(1,1) |
73 |
|
|
|
74 |
|
|
! set up the initial forces and temperatures. |
75 |
|
|
|
76 |
|
|
|
77 |
|
|
update_nlist = .true. |
78 |
|
|
nmflag = .false. |
79 |
|
|
|
80 |
|
|
call calc_temp(this_status%temp,this_status%kin_e) |
81 |
|
|
|
82 |
|
|
write(msg,*) "before run, T=", this_status%temp |
83 |
|
|
call info("init_dyna_loop", msg) |
84 |
|
|
|
85 |
|
|
|
86 |
|
|
call calc_forces(update_nlist,nmflag,& |
87 |
|
|
pe=this_status%pot_e) |
88 |
|
|
|
89 |
|
|
|
90 |
|
|
|
91 |
|
|
|
92 |
|
|
|
93 |
|
|
this_status%tot_e = this_status%pot_e + this_status%kin_e |
94 |
|
|
|
95 |
|
|
|
96 |
|
|
|
97 |
|
|
call dump_status(this_status) |
98 |
|
|
|
99 |
|
|
call dump_config(this_status%time) |
100 |
|
|
|
101 |
|
|
|
102 |
|
|
|
103 |
|
|
|
104 |
|
|
end subroutine init_dynamics_loop |
105 |
|
|
|
106 |
|
|
|
107 |
|
|
|
108 |
|
|
|
109 |
|
|
|
110 |
|
|
subroutine evolve_time(step,this_status,calc_pe,not_done) |
111 |
|
|
use velocity, ONLY : calc_temp |
112 |
|
|
integer, intent(in) :: step |
113 |
|
|
type (sim_status), intent(inout) :: this_status |
114 |
|
|
|
115 |
|
|
logical, intent(out) :: calc_pe, not_done |
116 |
|
|
|
117 |
|
|
calc_pe = .false. |
118 |
|
|
not_done = .true. |
119 |
|
|
this_status%time = dt * dble(step) |
120 |
|
|
|
121 |
|
|
! if true, next step we are going to write status |
122 |
|
|
if (mod(step + 1,write_config_steps).eq.0) then |
123 |
|
|
calc_pe = .true. |
124 |
|
|
endif |
125 |
|
|
|
126 |
|
|
if (mod(step,write_config_steps).eq.0) then |
127 |
|
|
call calc_temp(this_status%temp,this_status%kin_e) |
128 |
|
|
this_status%tot_e = this_status%pot_e + this_status%kin_e |
129 |
|
|
|
130 |
|
|
call dump_config( this_status%time ) |
131 |
|
|
call dump_status( this_status ) |
132 |
|
|
end if |
133 |
|
|
|
134 |
|
|
if (this_status%time.ge.run_time) then |
135 |
|
|
not_done = .false. |
136 |
|
|
end if |
137 |
|
|
|
138 |
|
|
end subroutine evolve_time |
139 |
|
|
|
140 |
|
|
|
141 |
|
|
|
142 |
|
|
subroutine dump_status(this_status,this_error) |
143 |
|
|
use file_units, ONLY : next_unit |
144 |
|
|
use definitions, ONLY : machdep_flush |
145 |
|
|
use status, ONLY : info |
146 |
|
|
|
147 |
|
|
type (sim_status) :: this_status |
148 |
|
|
integer, optional, intent(out) :: this_error |
149 |
|
|
logical :: is_opened |
150 |
|
|
integer :: err |
151 |
|
|
character(len=40) :: msg |
152 |
|
|
|
153 |
|
|
#ifndef MPI |
154 |
|
|
integer,parameter :: node = 0 |
155 |
|
|
#endif |
156 |
|
|
|
157 |
|
|
if ( node /= 0 ) then |
158 |
|
|
return |
159 |
|
|
endif |
160 |
|
|
|
161 |
|
|
if (present(this_error)) this_error = 0 |
162 |
|
|
|
163 |
|
|
! . Check to see if status unit has been opened |
164 |
|
|
! . if not then go ahead and open it. |
165 |
|
|
inquire(file = status_file, opened = is_opened) |
166 |
|
|
if ( .not. is_opened ) then |
167 |
|
|
status_unit = next_unit() |
168 |
|
|
open(file=status_file, unit=status_unit, status='replace', iostat=err, & |
169 |
|
|
action='write') |
170 |
|
|
|
171 |
|
|
if (err /=0 ) then |
172 |
|
|
write(msg,*) "Error opening status file " // status_file |
173 |
|
|
call info("DUMP STATUS", msg) |
174 |
|
|
if (present(this_error)) this_error = -1 |
175 |
|
|
end if |
176 |
|
|
write(unit=status_unit,fmt="(a55)") "# Time Temperature Potential Energy Total Energy " |
177 |
|
|
endif |
178 |
|
|
write(unit=status_unit,fmt=status_fmt, iostat = err) this_status%time, & |
179 |
|
|
this_status%temp, & |
180 |
|
|
this_status%pot_e, & |
181 |
|
|
this_status%tot_e |
182 |
|
|
if (err /= 0) then |
183 |
|
|
write(msg,*) "Error writing status file " // status_file |
184 |
|
|
call info("DUMP STATUS", msg) |
185 |
|
|
if (present(this_error)) this_error = -1 |
186 |
|
|
end if |
187 |
|
|
|
188 |
|
|
|
189 |
|
|
|
190 |
|
|
! . flush status unit |
191 |
|
|
call machdep_flush(status_unit) |
192 |
|
|
|
193 |
|
|
|
194 |
|
|
|
195 |
|
|
|
196 |
|
|
|
197 |
|
|
end subroutine dump_status |
198 |
|
|
|
199 |
|
|
|
200 |
|
|
|
201 |
|
|
|
202 |
|
|
end module dynamics_utilities |